Landings and flights of stairs: dimension tables, width features. Calculations for a private house

In modern construction, all sizes of landings and marches are strictly regulated by State Standards, approved during the existence of the Soviet Union and still in force - this is GOST 9818-85. This mainly applies to reinforced concrete structures and their assembly, as well as slopes, step sizes, and so on.

Below we will talk about such structures and norms, and you will also be shown a video in this article on this topic.

Installation of flights of stairs and landings is in progress
Installation of flights of stairs and landings is in progress

Features of sites and marches and requirements for them

Standard reinforced concrete flights
Standard reinforced concrete flights

In the manufacture and installation of reinforced concrete structural blocks for arranging stairs, parameters such as length, width, thickness, number of steps and their height, as well as strength characteristics of finished products are taken into account. In addition, the parameters of the building where they will be installed are also taken into account, therefore their production has different dimensions.

Tables of dimensions of LM and LP

For marking stair flights, the abbreviation LM is used, and for staircases LP. They are followed by numbers indicating the differences.

Staircase marking Compliance (GOST) Dimensions in mm Weight in kg Volume in m3
LM 12.19.09-5-d 9818 1860x1200x900 1440 0?576
LM 19.13.5.09-5-d 9818 1860x1350x900 1620 0,648
LM 19.13.09-5-d 9818 1860x1300x900 1560 0,624
LM 09.22.10.5-5-d 9818 2160x900x1050 1250 0,5
LM 22.10.10.5-5-d 9818 2160x1000x1050 1390 0,556
LM 10/28/13.5-5-d 9818 2760x1000x1350 1760 0,704
LM 28.12.5.13.5-5-d 9818 2760x1250x1350 2200 0,88
LM 19.12.5.09-5-d 9818 1860x1250x900 1500 0,6
LM 22.10.5.10.5-5-d 9818 2160x1050x1050 1460 0,584
LM 22.11.5.10.5-5-d 9818 2160x1150x1050 1595 0,638
LM 22.1110.5-5-d 9818 2160x1100x1050 1525 0,61
LM 22.12.5.10.5-5-d 9818 2160x1250x1050 1735 0,6928
LM 22.12.10.5.-5-d 9818 2160x1200x1050 1655 0,666
LM 22.13.10.5-5-d 9818 2160x1350x1050 1875 0?75
LM 22.13.10.5-5-d 9818 2160x1300x1050 11805 0,722
LM22.09.12-5-d 9818 2460x900x1200 1415 0,566
LM 25.10.5.12-5-d 9818 2460x1050x1200 1685 0,674
LM 10.25.12-5-d 9818 2460x1000x1200 1575 0,63
LM 25.11.5.12-5-d 9818 2460h1150h1200 1845 0,738
LM 11/25/12-5-d 9818 2460x1100x1200 1730 0,692
LM 25.12.5.12-5-d 9818 2460x1250x1200 1965 0?786
LM 12/25/12-5-d 9818 2460x1200x1200 1925 0,77
LM 25.13.5.12-5-d 9818 2460x1350x1200 2125 0?85
LM 25.13.12-5-d 9818 2460x1300x1200 2045 0,818
LM 09.20.13.5-5-d 9818 2760x900x1350 1585 0,634
LM 28.10.5.13.5-5-d 9818 2760x1050x1350 1850 0?74
LM 28.11.5.13.5-5-d 9818 2760x1150x1350 2025 0,81
LM 28.11.13.5-5-d 9818 2760x1100x1350 1935 0,774
LM 28.12.13.5-5-d 9818 2760x1200x1350 2110 0,844
LM 28.13.5.13.5-5-d 9818 2760x1350x1350 2375 0,95
LM 28.13.13.5-5-d 9818 2760x1300x1350 2290 0,916
LM 30.10.5.14-5-d 9818 2760x1050x1400 1850 0,74
LM 10.10.14-5-d-2 9818 2760x1950x1400 1710 0,684
LM 30.11.5.14-5-d-2 9818 2760x1150x1400 2025 0,81
LM 11/30/14-5-d-2 9818 2760x1100x1400 1880 0,752
LM 12/30/14-5-d-2 9818 2760x1200x1400 2115 0,846
LM 09/30/15-5-d 9818 3060x900x1500 1750 0,7
LM 31.10.5.15-5-d 9818 3060x1050x1500 2050 0,82
LM 10/31/15-5-d 9818 3060x1000x1500 1945 0,778
LM 31.11.5.15-5-d 9818 3060x1150x1500 2225 0,89
LM 31.11-15-5-d 9818 3060x1100x1500 2150 0,86
LM 31.12.5.15-5-d 9818 3060x1250x1500 2430 0,972
LM 12/31/15-5-d 9818 3060x1200x1500 2325 0,93
LM 31.13.5.15-5-d 9818 3060x1350x1500 2575 1,03
LM 31.13.15-5-d 9818 3060x1300x1500 2530 1,012
LM 34.10.5.17-5-d 9818 3360x1050x1650 2235 0,894
LM 34.11.5.17-5-d 9818 3360x1150x1650 2445 0,978
LM 34.12.17-5-d 9818 3360x1200x1650 2550 1,02
LM 34.13.5.17-5-d 9818 3360x1350x1650 2825 1,13
LM 37.09.18-5-d 9818 3660x900x1800 2085 0,834
LM 37.10.5.18-5-d 9818 3660x1050x1800 2425 0,97
LM 37.10.18-5-d 9818 3660x1000x1800 2320 0,928
LM 31.11.5.18-5-d 9818 3660x1150x1800 2655 1,062
LM 37.11.18-5-d 9818 3660x1100x1800 2550 1,02
LM 37.12.5.18-5-d 9818 3660x1250x1800 2900 1,16
LM 37.12.18-5-d 9818 3660x1200x1800 2775 1,11
LM 37.13.5.18-5-d 9818 3660x1350x1800 3125 1,25
LM 37.13.18-5-d 9818 3660x1300x1800 3015 1,206
LM 09.19.09.-5-d 9818 1860x900x900 1080 0?432
LM 19.10.09-5-d 9818 1860x1000x900 1200 0,48
LM 19.10.5.09-5-d 9818 1860x1050x900 1260 0,506
LM 19.11.09-5-d 9818 1860x11100x900 1320 0?528
LM 19.11.5.09-5-d 9818 1860x1150x900 1380 0,552

Stairways (LM)

Staircase marking Compliance (GOST) Dimensions in mm Weight in kg Volume in m3
LMP 43.11.15-4-1 GOST 9818-85 44250x1050x1500 2500 1,0
LMP43.11.15-4-2 GOST 9818 4250x1050x1500 2475 0,99
LMP 57.11.15-5r GOST 9818 5650x1050x1500 2330 0,032
LMP57-11-14-5 Series 1.050.1.2.v.1.2 5650x1150x1400 2200 0,9
LMP 60-11-17-5 II-04-7 5980x1150x150 2600 1,04
LMP 60-11-17-5-3 II-04-7 4790x1150x150 2,1 0,84
LMP 62-11-15 GOST 9818 6200x1150x240 2450 0,98

Staircases with a platform (LMP)

Staircase marking Compliance (GOST) Dimensions in mm Weight in kg Volume in m3
2LMF 39-12-17-5 1.251.1-4 3913x1200x295 1290 0,52
2LMF 39-14-17-5 1.251.1-4 3913x1350x1650 1420 0,568
2LMF 3914-17-5y 1.251.1-4 3913x1350x1650 1243 0,5
2LMF 42-14-18-5 1.251.1-4 4249x1800x1200 1530 0,612

Staircases with a frieze step (LMF)

Some explanations for marking: 27 - length; 11- width; 14- vertical height; 4 - design load.

Photo of the site with the letter designation of the parameters
Photo of the site with the letter designation of the parameters
Site marking Platform dimensions in mm Weight in tons
L (width) B (Length) H (height)
1LP 30-15-4 2980 1500 320 1,4
1ЛП 30-15В-4 3040 1600 320 2,4
1LP 30-18-4 2980 1800 320 2,9
2LP 22-12-4 2200 1300 320 1,035
2LP 22-12-4K 2200 1300 220 1,035
2LP 22-15 2200 1600 220 1,2
2LP 22-15-4 2200 1600 320 1,2
2LP 22-15-4K 2200 1600 320 1,2
2LP 22-18 2480 1900 320 1,37
2LP 22-18-4 2480 1900 320 1,37
2LP 22-18-4K 2200 1900 320 1,37
2LP 25-12 2500 1300 320 1,16
2LP 25-12-4 2500 1300 320 1,16
2LP 25-12-4K 2500 1300 320 1,16
2LP 25-12V-4K 2780 1300 320 1,16
2LP 25-15-4 2480 1600 320 1,345
2LP 25-15-4K 2480 1600 320 1,345
2ЛП 25-15В-4K 2500 1600 320 1,37
2LP 25-18-4 2500 1900 320 1,463
2LP 25-18-4ML 2500 1900 320 1,395
2LP 25-18-4MLV 2500 1900 320 1,47
2LP 25-18-4K 2500 1800 280 1,533
LP 1-26-18 2680 1860 160 1,942
LP 15-14 1385 1490 300 0,585
LP 1P 2820 1370 320 1,14
LP 1P1 2820 1370 320 1,14
LP 22-16 2680 1860 160 1,865
LP 22-15 2480 1600 320 1,15
LP 22-16-1 2440 1440 300 0,397
LP 24-14 2600 1150 250 0,775
LP 25-15-4K 2500 1600
LP 28-13 3040 1060 350 0,87
LP 28-15 3040 1260 350 0,98
LP 28-17 3000 1540 250 1,1
LP 30-13 3020 1330 200 1,148
LP 30-18 3020 1830 320 1,875
LP 30-18-1 3020 1830 320 1,875
LP 32-18 3180 1780 320 4,527
LPP 14-12V 1440 1200 240 0,5
BOB 14-13V 1440 1325 240 0,6
LPP 14-15V 1440 1475 240 0,6
BOB 15-1 0,413
LPP 15-15V 1540 1490 240 0,75
BOB 15-6 0,25
LPP 16-15V 1610 1490 240 0,775
LPF 25-10-5 2500 990 350 0,9
LPF 25-11-5 2500 1140 350 0,98
LPF 25-13-5 2500 1290 350 1,075
LPF 28-11-5 2800 1140 350 1,1
LPF 28-13-5 3080 1290 350 1,195
LPF 31-13-5 3100 1290 350 1,315
LPR 22-15K 2480 1600 320 1,2
LPR 22-18K 2480 1900 320 1,4
Decision maker 25-12 2780 1300 320 1,13
Decision maker 25-18 2500 1900 320 1,73
DM 25-18 MLA 2500 1900 320 1,395
Decision maker 25-18 MLB 2500 1900 320 1,4
LPR 25-18 MLS 2500 1900 320 1,4

Staircases

Some explanations for labeling: LP and LPS - staircases; 1ЛП - for marches of LM type; 2ЛП - ribbed platform for LM; LPF - ribbed platform for LMF; LPP - ribbed platform and p. / Platform for LMP; LPR - ribbed platform; K - support console.

Width features

Width parameters: a) minimum; b) standard; c) comfortable
Width parameters: a) minimum; b) standard; c) comfortable
  • In addition to the slope and length, flights of stairs and landings differ in width, which is of great importance not only for the convenience of movement, but also for the safety of people in emergency situations at the time of urgent evacuation.In the image above, you see three conditioned parameters, where the minimum is considered at a size of 60-80 cm and is recommended only for little-visited rooms; standard - from 90 to 120 cm - recommended for everyday use; comfortable - from 125 to 150 cm - for elite residential buildings and public spaces.
  • When designing houses, developers usually use a standard staircase width., which you are surely convinced of every day, entering the entrances of various residential buildings and most office and industrial buildings.
    But such staircases and landings are sometimes difficult to fit into the project of your own house - we are not talking about the material, but about the parameters. Therefore, the private sector is better known for narrow staircases up to 60 cm, and sometimes even 50 cm wide spans can be found, which is extremely unsafe in emergency situations.
The most optimal parameters for sites
The most optimal parameters for sites
  • In any case, the arrangement of flights of stairs and landings must match in width, that is, the span can in no way be wider than the landing. and the same rule applies when stair flights with half-platforms are designed. In height, the site can only be one step higher, no more, and the same level of difference is acceptable for two-level sites. In cases where the staircase does not turn, the length of the transition plane must be at least 60-64 cm (the average step of a person).
U-shaped design
U-shaped design
  • In most cases, when staircases with landings are designed in a private house, the problem is that you have to make a U-shaped staircase (with a 180⁰ turn). And this means that when arranging a structure, you need to accommodate two widths plus a gap between them, which, at least, will turn out to be 5-10 cm - all this requires a certain amount of space in the room.
    Therefore, in such situations, convenience and safety are often compromised by making narrower spans to save room space.

Calculations for a private house

Convenience and safety of operation are related to the angle of inclination
Convenience and safety of operation are related to the angle of inclination
  • When the installation of staircases and marches is carried out with your own hands, you definitely need to make calculations for the slope and the number of steps... So, the optimal slope, as a rule, is 30⁰-35⁰, but with a shortage of free space in the house, it is made much steeper.

A warning. A steep slope, which is considered to be an angle of 40⁰-45⁰, is quite acceptable for living quarters, but only physically strong, healthy people can feel free on it.
For the average person, not to mention children and the elderly, the instruction advises to equip more gentle stairs.

The calculation of the steps can be done using the method of a right-angled triangle.
The calculation of the steps can be done using the method of a right-angled triangle.
  • Let's imagine that the height of the first floor is 3m and we need to calculate a flight of stairs with a landing... Then we take into account the thickness of the floor on the second floor and, for example, it will be 0.2m, then the total height will be 3.2m, and in this interval we will install 2 marches, 1.6m high (the platform will be in the middle). For such sizes, it will be convenient for us to make steps 16 cm high - 10 pieces for each march.
  • Now we select the required tread width and for this we will start from the already known value of the average step of a person, using the formula 2hsteps+ dtread≈60≈64 cm, then dtread it will turn out from 28 to 32 cm, but we will stop at 30. This means that the segment AC we get 30 * 10 = 3.0m.
  • Now we need to find out the length of the stringer or segment AB, and for this we use the formula d2+ e2= x2=1,62+32= 2.56 + 9 = 11.56. But now we extract √11.56 = 3.4m, that is, it will be the length of the stringer or bowstring of the ladder. When calculating the area that the staircase will take, do not forget to add the length of the platform, for example, (3.0 + 0.6) * (0.9 + 0.9 + 0.1) = 6.84m2.
Wooden railing
Wooden railing
  • During construction, the fencing of stair flights and landings is subject to GOST 25772-83 (clauses 1.2, 1.3), which provides for a height of the handrail of at least 0.9 m together with handrails.For wooden structures, balusters should be installed one for each step, and on the site, as well as for the fence of the second floor, it is better to keep the step the same. In our case, it will turn out to be 30 cm.

Advice. To calculate the length of the handrails on marches, you can use the already known formula d 2 + e 2 = x 2 by drawing a right-angled triangle of the desired scale.

Conclusion

When arranging a staircase, its price will depend not only on the amount of materials, but also on the complexity of production. The article considered a simpler option, with straight platforms, but there are also options with winder rotary steps.

flwn.imadeself.com/33/
Add a comment

;-) :| : x : twisted: : smile: : shock: : sad: : roll: : razz: : oops: : o : mrgreen: : lol: : idea: : grin: : evil: : cry: : cool: : arrow: :???: :?: :!:

We advise you to read:

14 rules for saving energy