Ladder with handrails - Standard LM-02: tables for flights and staircases

For private construction, small-sized lightweight wooden structures are mainly used, such as the Favorit LMP-11 left-hand staircase or Standard LM-02, which you see below. However, for the global solution of problems of communication between floors, reinforced concrete marches with platforms of different widths are usually mounted, but for them the average angle of inclination is preserved.

Ladder Standard LM-02
Ladder Standard LM-02

Of course, the price of wooden and reinforced concrete stairs is different, as well as the instructions for their installation, although they all serve the same purpose - for descent and ascent.

Variety of stairs

Reinforced concrete stairs are a beautiful and practical architectural element
Reinforced concrete stairs are a beautiful and practical architectural element

The difference in reinforced concrete and wooden flights of stairs is, of course, in the material, but when choosing the main criterion is the ability to install a particular structure in one place or another. So, the ladder of the LM-02 standard (see the photo under the title) will fit where the reinforced concrete march does not enter in any way, that is, for lightweight wooden products, you can arbitrarily change the angle of inclination, making it even 50⁰ or more. In addition, an exclusive structure can be made of wood, taking into account the parameters of a particular room, without resorting to certain standards.

Recommendation. If the estimated angle of inclination is more than 60⁰-65⁰, then it is more convenient and safer to use attached or folding ladders, where not handrails are used for insurance when going up and down, but the steps themselves, that is, horizontal profiles (bars).

Tables for flights and stairs

Reinforced concrete staircases: basic facts and uses
Reinforced concrete staircases: basic facts and uses

 

Marking GOST Dimensions in mm (LxBxH) Weight in kg Volume in m3
LM 12.19.09-5-d 9818 1860x1200x900 1440 0?576
LM 19.13.5.09-5-d 9818 1860x1350x900 1620 0,648
LM 19.13.09-5-d 9818 1860x1300x900 1560 0,624
LM 09.22.10.5-5-d 9818 2160x900x1050 1250 0,5
LM 22.10.10.5-5-d 9818 2160x1000x1050 1390 0,556
LM 10/28/13.5-5-d 9818 2760x1000x1350 1760 0,704
LM 28.12.5.13.5-5-d 9818 2760x1250x1350 2200 0,88
LM 19.12.5.09-5-d 9818 1860x1250x900 1500 0,6
LM 22.10.5.10.5-5-d 9818 2160x1050x1050 1460 0,584
LM 22.11.5.10.5-5-d 9818 2160x1150x1050 1595 0,638
LM 22.1110.5-5-d 9818 2160x1100x1050 1525 0,61
LM 22.12.5.10.5-5-d 9818 2160x1250x1050 1735 0,6928
LM 22.12.10.5.-5-d 9818 2160x1200x1050 1655 0,666
LM 22.13.10.5-5-d 9818 2160x1350x1050 1875 0?75
LM 22.13.10.5-5-d 9818 2160x1300x1050 11805 0,722
LM22.09.12-5-d 9818 2460x900x1200 1415 0,566
LM 25.10.5.12-5-d 9818 2460x1050x1200 1685 0,674
LM 10.25.12-5-d 9818 2460x1000x1200 1575 0,63
LM 25.11.5.12-5-d 9818 2460h1150h1200 1845 0,738
LM 11/25/12-5-d 9818 2460x1100x1200 1730 0,692
LM 25.12.5.12-5-d 9818 2460x1250x1200 1965 0?786
LM 12/25/12-5-d 9818 2460x1200x1200 1925 0,77
LM 25.13.5.12-5-d 9818 2460x1350x1200 2125 0?85
LM 25.13.12-5-d 9818 2460x1300x1200 2045 0,818
LM 09.20.13.5-5-d 9818 2760x900x1350 1585 0,634
LM 28.10.5.13.5-5-d 9818 2760x1050x1350 1850 0?74
LM 28.11.5.13.5-5-d 9818 2760x1150x1350 2025 0,81
LM 28.11.13.5-5-d 9818 2760x1100x1350 1935 0,774
LM 28.12.13.5-5-d 9818 2760x1200x1350 2110 0,844
LM 28.13.5.13.5-5-d 9818 2760x1350x1350 2375 0,95
LM 28.13.13.5-5-d 9818 2760x1300x1350 2290 0,916
LM 30.10.5.14-5-d 9818 2760x1050x1400 1850 0,74
LM 10.10.14-5-d-2 9818 2760x1950x1400 1710 0,684
LM 30.11.5.14-5-d-2 9818 2760x1150x1400 2025 0,81
LM 11/30/14-5-d-2 9818 2760x1100x1400 1880 0,752
LM 12/30/14-5-d-2 9818 2760x1200x1400 2115 0,846
LM 09/30/15-5-d 9818 3060x900x1500 1750 0,7
LM 31.10.5.15-5-d 9818 3060x1050x1500 2050 0,82
LM 10/31/15-5-d 9818 3060x1000x1500 1945 0,778
LM 31.11.5.15-5-d 9818 3060x1150x1500 2225 0,89
LM 31.11-15-5-d 9818 3060x1100x1500 2150 0,86
LM 31.12.5.15-5-d 9818 3060x1250x1500 2430 0,972
LM 12/31/15-5-d 9818 3060x1200x1500 2325 0,93
LM 31.13.5.15-5-d 9818 3060x1350x1500 2575 1,03
LM 31.13.15-5-d 9818 3060x1300x1500 2530 1,012
LM 34.10.5.17-5-d 9818 3360x1050x1650 2235 0,894
LM 34.11.5.17-5-d 9818 3360x1150x1650 2445 0,978
LM 34.12.17-5-d 9818 3360x1200x1650 2550 1,02
LM 34.13.5.17-5-d 9818 3360x1350x1650 2825 1,13
LM 37.09.18-5-d 9818 3660x900x1800 2085 0,834
LM 37.10.5.18-5-d 9818 3660x1050x1800 2425 0,97
LM 37.10.18-5-d 9818 3660x1000x1800 2320 0,928
LM 31.11.5.18-5-d 9818 3660x1150x1800 2655 1,062
LM 37.11.18-5-d 9818 3660x1100x1800 2550 1,02
LM 37.12.5.18-5-d 9818 3660x1250x1800 2900 1,16
LM 37.12.18-5-d 9818 3660x1200x1800 2775 1,11
LM 37.13.5.18-5-d 9818 3660x1350x1800 3125 1,25
LM 37.13.18-5-d 9818 3660x1300x1800 3015 1,206
LM 09.19.09.-5-d 9818 1860x900x900 1080 0?432
LM 19.10.09-5-d 9818 1860x1000x900 1200 0,48
LM 19.10.5.09-5-d 9818 1860x1050x900 1260 0,506
LM 19.11.09-5-d 9818 1860x11100x900 1320 0?528
LM 19.11.5.09-5-d 9818 1860x1150x900 1380 0,552

 

Stairways (LM)

Staircases LMP. Parameter designation with letters
Staircases LMP. Parameter designation with letters

 

Marking GOST Dimensions in mm (LxBxH) Weight in kg Volume in m3
LMP 43.11.15-4-1 GOST 9818-85 44250x1050x1500 2500 1,0
LMP43.11.15-4-2 GOST 9818 4250x1050x1500 2475 0,99
LMP 57.11.15-5r GOST 9818 5650x1050x1500 2330 0,032
LMP57-11-14-5 Series 1.050.1.2.v.1.2 5650x1150x1400 2200 0,9
LMP 60-11-17-5 II-04-7 5980x1150x150 2600 1,04
LMP 60-11-17-5-3 II-04-7 4790x1150x150 2,1 0,84
LMP 62-11-15 GOST 9818 6200x1150x240 2450 0,98

 

Staircases with a platform (LMP)

LMF. Parameter designation with letters
LMF. Parameter designation with letters

 

Marking GOST Dimensions in mm (LxBxH) Weight in kg Volume in m3
2LMF 39-12-17-5 1.251.1-4 3913x1200x295 1290 0,52
2LMF 39-14-17-5 1.251.1-4 3913x1350x1650 1420 0,568
2LMF 3914-17-5y 1.251.1-4 3913x1350x1650 1243 0,5
2LMF 42-14-18-5 1.251.1-4 4249x1800x1200 1530 0,612

 

Staircases with a frieze step (LMF)

Explanations on marking: 27 - length; 11- width; 14- vertical height; 4 - design load.

In the marking of reinforced concrete structures, both letters and numbers are present, for example, staircases LM 12 to 12 are designated as LM 12/25/12-5-d and have parameters of 2460x1200x1200 mm. That is, the digital symbols in the marking here show the value in decimeters, but in a rounded form. This, of course, is not only the LM 12 by 12 staircase, but also other spans that you see in the upper table.

Area. Parameter designation with letters
Area. Parameter designation with letters

 

Site marking Platform dimensions in mm Weight in tons
L (width) B (Length) H (height)
1LP 30-15-4 2980 1500 320 1,4
1ЛП 30-15В-4 3040 1600 320 2,4
1LP 30-18-4 2980 1800 320 2,9
2LP 22-12-4 2200 1300 320 1,035
2LP 22-12-4K 2200 1300 220 1,035
2LP 22-15 2200 1600 220 1,2
2LP 22-15-4 2200 1600 320 1,2
2LP 22-15-4K 2200 1600 320 1,2
2LP 22-18 2480 1900 320 1,37
2LP 22-18-4 2480 1900 320 1,37
2LP 22-18-4K 2200 1900 320 1,37
2LP 25-12 2500 1300 320 1,16
2LP 25-12-4 2500 1300 320 1,16
2LP 25-12-4K 2500 1300 320 1,16
2LP 25-12V-4K 2780 1300 320 1,16
2LP 25-15-4 2480 1600 320 1,345
2LP 25-15-4K 2480 1600 320 1,345
2ЛП 25-15В-4K 2500 1600 320 1,37
2LP 25-18-4 2500 1900 320 1,463
2LP 25-18-4ML 2500 1900 320 1,395
2LP 25-18-4MLV 2500 1900 320 1,47
2LP 25-18-4K 2500 1800 280 1,533
LP 1-26-18 2680 1860 160 1,942
LP 15-14 1385 1490 300 0,585
LP 1P 2820 1370 320 1,14
LP 1P1 2820 1370 320 1,14
LP 22-16 2680 1860 160 1,865
LP 22-15 2480 1600 320 1,15
LP 22-16-1 2440 1440 300 0,397
LP 24-14 2600 1150 250 0,775
LP 25-15-4K 2500 1600
LP 28-13 3040 1060 350 0,87
LP 28-15 3040 1260 350 0,98
LP 28-17 3000 1540 250 1,1
LP 30-13 3020 1330 200 1,148
LP 30-18 3020 1830 320 1,875
LP 30-18-1 3020 1830 320 1,875
LP 32-18 3180 1780 320 4,527
LPP 14-12V 1440 1200 240 0,5
BOB 14-13V 1440 1325 240 0,6
LPP 14-15V 1440 1475 240 0,6
BOB 15-1 0,413
LPP 15-15V 1540 1490 240 0,75
BOB 15-6 0,25
LPP 16-15V 1610 1490 240 0,775
LPF 25-10-5 2500 990 350 0,9
LPF 25-11-5 2500 1140 350 0,98
LPF 25-13-5 2500 1290 350 1,075
LPF 28-11-5 2800 1140 350 1,1
LPF 28-13-5 3080 1290 350 1,195
LPF 31-13-5 3100 1290 350 1,315
LPR 22-15K 2480 1600 320 1,2
LPR 22-18K 2480 1900 320 1,4
Decision maker 25-12 2780 1300 320 1,13
Decision maker 25-18 2500 1900 320 1,73
DM 25-18 MLA 2500 1900 320 1,395
Decision maker 25-18 MLB 2500 1900 320 1,4
LPR 25-18 MLS 2500 1900 320 1,4

 

Stairways (LP)

Some explanations for labeling: LP and LPS - staircases; 1ЛП - for marches LM type; 2ЛП - ribbed platform for LM; LPF - ribbed platform for LMF; LPP - ribbed platform and p. / Platform for LMP; LPR - ribbed platform; K - support console.

Applying parameters at home

Convenience and safety of operation are related to the angle of inclination
Convenience and safety of operation are related to the angle of inclination
  • In the graphical diagram, you can see the most used slopes for stair flights, used both in everyday life and in production, but, as mentioned above, it is not always possible to apply the desired degree of slope. The reason is quite trivial - there is no free space for arrangement. Therefore, it is necessary to increase this angle, sometimes even neglecting certain norms (this happens especially often in the private sector).
Ladder LM-1 on the central stringer
Ladder LM-1 on the central stringer
  • I would like to draw your attention to some coincidences when marking on products from different materials, where the same symbols mean different products. So, the reinforced concrete staircase LM-1 is widely used in industrial and civil construction for floors no more than 3 m high, moreover, their number can be unlimited. But the same marking LM-1 can also denote a metal staircase on the central stringer, made in the form of a screw, just here the letter M means metal, and in the previous version it means a march.
  • For self-construction of a residential building or overhaul with their own hands, metal and wooden structures are most often used. And the point here is no longer in cost, but in the possibility of accommodation in a limited living space.
Staircase width: a) minimum; b) standard; c) comfortable
Staircase width: a) minimum; b) standard; c) comfortable
  • For all structures of this type, there are three main parameters in terms of throughput or width, which determine not only certain conveniences, but also the safety of people during emergency evacuation. So, for the minimum width of the stairs, 70-80 cm is enough and such devices are most often used for rarely visited premises, the standard width is from 90 to 120 cm (in almost all entrances of multi-storey buildings) and comfortable - 125-150 cm, for elite and public buildings ...

Conclusion

The choice and installation of flights of stairs determines not only the aesthetic side of the issue in the construction of buildings and not even a question of comfort or presentability. First of all, it is traffic safety, which in force majeure circumstances can save human lives.

flwn.imadeself.com/33/
Add a comment

;-) :| : x : twisted: : smile: : shock: : sad: : roll: : razz: : oops: : o : mrgreen: : lol: : idea: : grin: : evil: : cry: : cool: : arrow: :???: :?: :!:

We advise you to read:

14 rules for saving energy