1 filtering respirator respirator anti-dust r-2 table of contents purpose, performance characteristics and principle of operation of the respirator composition and completeness of the respirator marking. - presentation

Specifications

Indicator name PTS "Profi-M"
P / p. Specifications Indicator value
1 Weight of equipped vehicle without rescue device no more than 10.5 kg
2 Working air pressure in the cylinder 29.4 MPa (300 kgf / cm2)
3 The pressure gauge must have a calibration interval at least 2 years
4 Panoramic mask PTS "Obzor-Mr"
5 Air metal composite cylinder:

· Brand

Capacity

· operating pressure

· weight

· life time

VMK 6.8-139-300

(or similar)

6.8 liters

not less than 300 bar

no more than 4.1 kg

at least 15 years

6 Dimensions of the device 640 × 320 × 230 mm
7 Time of protective action (with pulmonary ventilation 30 l / min. And temperature +25 C) at least 60 minutes
8 Operating temperature range from -50 to +60 C
9 Overpressure in the mask space of the facepiece at zero flow 250 ÷ 450 Pa

(25 ÷ 45 mm water column)

Indicator name PTS "Profi-M"
P / p. Specifications Indicator value
10 Reduced pressure at the outlet of the reducer 0.55 ÷ 0.9 MPa

(5.5 ÷ 9 kgf / cm2)

11 Relief valve opening pressure 1.2 ÷ 2.0 MPa

(12 ÷ 20 kgf / cm2)

12 Alarm pressure adjustable
13 The actual resistance to breathing on exhalation, during the entire time of protective action with pulmonary ventilation 30 l / min.) not more than 350 Pa

(35 mm water column)

14 The number of cycles of loading (filling) the cylinder of the apparatus between zero and working pressure not less than 5000
15 Gearbox service life, without re-certification at least 10 years
16 Service life of the front parts of the device at least 10 years
17 Service life (operation) of the device at least 10 years

The operating manual and the passport are available by clicking the download button at the bottom of the article

Design advantages

  • an original harness with thermo-fire-resistant straps and a plastic ergonomically profiled backrest, equipped with a chest strap and soft shoulder pads, which significantly reduces the load on the user's back and provides comfort when working;
  • universal fastening system, suitable for all types of cylinders, is characterized by simplicity and reliability of fixation;
  • the lung governed demand valve maintains a uniform excess pressure in the undermask space of the facial part at various respiratory loads;
  • the device includes an adapter with a quick-disconnect connection, which allows the connection of a rescue device.

Specifications [edit]

  • Time of protective action during work of medium severity, h, not less than 4
  • Oxygen reserve in the cylinder at a pressure of 20 MPa (200 kgf / cm²), l 400
  • Weight of KhP-I in regenerative cartridge, kg, not less than 2.0
  • Cooling element mass, kg, not less than 0.75
  • Oxygen supply to the respirator system, l / min:
    • constant 1.3-1.5
    • pulmonary-automatic, not less than 70
    • emergency valve (bypass), not less than 150-60
  • Vacuum pressure at which the lung valve opens, Pa (mm wg) 100-300 (10-30)
  • Excessive pressure at which the excess valve opens, Pa (mm of water column) 100-300 (10-30)
  • Useful capacity of the breathing bag, l, not less than 4.5
  • Overall dimensions (without breathing hoses and shoulder straps), mm:
    • length 450 ± 5
    • width 375 ± 2
    • height 165 ± 5
  • Weight, kg, no more:
    • respirator without face pieces, cooling element and refrigerator cover 11.0
    • mouthpiece device with headband 0.16
    • respiratory mask 0.63
    • cooling element with refrigerator cover 0.80

Device and principle of operation

This respirator model has a rather simple device - it consists of three layers of different materials. The first layer is polyurethane, which is characterized by a protective color, has the appearance of a film and does not allow dust contained in the air to pass through. The device also includes 2 valves, between which there is a second protective layer made of polymer fibers. The main task of this layer is additional filtration of the air inhaled by a person. The third layer is made of a thin air-permeable film, in which the inhalation valves are mounted separately.

The front of the protective device has an outlet valve. To make it convenient to use the respirator, manufacturers additionally equip it with a nose clip and soft elastic straps, thanks to which the device is securely fixed on the head and does not slip on the eyes or chin.

The inhaled air enters through the filters, being cleaned at the same time, and the exhaust air is discharged through a separate valve. Using such a device, a person almost completely protects his body from the negative effects of dust.

Personal respiratory protection

Filtering gas masks

Respirator RPG-67 Exit to section Respirator RPG-67 AVEK
Respirator RPG-67 brand A, B, KD

Respirator RPG-67 is designed to protect the human respiratory system from harmful impurities present in the atmosphere in the form of vapors and gases.

It provides protection of the human respiratory system in various industries, in agriculture when working with pesticides and fertilizers, as well as in domestic conditions. Available in three sizes (1st, 2nd, 3rd).

The RPG-67 respirator consists of a rubber half mask, two filter cartridges, plastic cuffs with inhalation valves, an exhalation valve with a protective screen and a headband. Supplied with 4 brands of gas mask filter cartridges (see table).

The filter cartridges of a respirator are specialized for their intended purpose, depending on the physicochemical and toxic properties of harmful impurities and differ in the composition of absorbers and labeling. Replacement filter cartridges can be supplied separately.

Nomenclature of filter cartridges:

Brand

Filter cartridge markings

The list of harmful impurities from which this brand of respirator protects separately and in a mixture

Time of protective action at concentration

0.2 mg / l

0.04mg / l

A

RPG-67-A

Vapors of organic compounds (gasoline, kerosene, benzene and its homologues, alcohols, ethers, carbon disulfide, aniline, etc.)

Benzene C = 10 mg / l 60 min.

38 hours

144 hrs

V

RPG-67-B

Acid gases (sulfur dioxide, hydrogen sulfide, hydrogen chloride, vapors of chlorine and organophosphorus pesticides)

Sulfurous anhydride

С = 2mg / l ZO min.

11 hours

56 hours

G

RPG-67-G

Mercury vapors, organic mercury toxic chemicals based on ethylmercuric chloride

Mercury vapors O0.01mg / d 20h.

No more than 20 hours.

No more than 20 hours.

CD

RPG-67-KD

Ammonia, hydrogen sulfide and mixtures thereof

Ammonia C = 2mg / l ZO min. Hydrogen sulfide

С = 2mg / l ZO min,

8 hours

28 hours

Technical characteristics of the RPG-67 respirator:

1. Resistance to a constant air flow, at a volumetric air flow (30 dm3 / min) Pa (mm water column), no more:
- on inspiration 88.2 (9)
- on exhalation 58.8 (6)

2. Working temperature range from - 40. ° С to - 50. ° С

3. Weight, no more than 0.300 kg.

4. Guaranteed shelf life:
- respirator 3 years from the date of manufacture
- filter cartridge of grades "A", "B", "KD" 3 years
- filter cartridge of the "G" brand for 1 year.

5. Packing:
- respirator - 40 pcs. (cardboard box)
- zapatron - 500 pcs. (wooden box)

The RPG-67 gas mask is designed to protect the human respiratory system from harmful substances present in the atmosphere of workplaces in the form of vapors and gases.Respirator set RPG-67 includes: - rubber mask; - two filter cartridges of one of 4 brands.

The filter cartridges of a respirator are specialized for their intended purpose, depending on the physicochemical and toxic properties of harmful impurities and differ in the composition of absorbers and labeling (see table).

The RPG-67 respirator provides protection of the human respiratory system in various industries in agriculture when working with pesticides and fertilizers, as well as in domestic conditions.

Available in three sizes (1st, 2nd, 3rd).

Replaceable filter cartridges are supplied with the respirator, but can also be supplied separately by agreement with the consumer.

Protective characteristics of industrial filter respirators

Brand of boxes (cartridges) of the absorbing system Control substance Concentration Time of protective action, min.
RPG-67 RU-60M PFPM
Box without filter Filter box
A benzene 10.0 mg / l 60 30 60 60
V Sulfurous anhydride 2.0 mg / l 50 30 50 50
TO ammonia 2.0 mg / l 30
CD ammonia 2.0 mg / l 30 20
hydrogen sulfide 2.0 mg / l 50 20
G Mercury vapor 0.01 mg / l 1200 900

The order of inclusion in a respirator and work in it [edit]

Before descending into the mine and before entering the respirator, it is necessary to conduct a cursory check to determine the operability of the main components, for which check:

  • tightness of a respirator with a mouthpiece or with a mask,
  • serviceability of the lung valve,
  • serviceability of the bypass,
  • serviceability of the excess valve,
  • oxygen supply;
  • serviceability of the signal whistle.

To check the tightness of the respirator, suck the air from the respirator system to the maximum possible limit. If, while holding the breath for 3-8 seconds, further suction is not possible, then the respirator is airtight.
To check the tightness of a respirator with a mask, put on a mask and, without opening the cylinder valve, squeeze the exhalation hose with your hand, pull the edge of the mask to exhale. Release the edge of the mask, inhale and exhale again into the atmosphere. With the next inhalation under the mask, a stable vacuum pressure should be formed.
Open the cylinder valve and take a deep breath. Free inhalation and the characteristic noise of the pulmonary demand valve indicate its serviceability.

To check the health of the lung demand valve, exhale into the respirator system, open the cylinder valve and take one or two deep breaths. The absence of resistance on inhalation and the sharp hissing sound of oxygen entering the breathing bag indicate the health of the lung demand valve.

To check if the bypass is working properly, press its button. At the same time, the breathing bag should be quickly filled with oxygen, a sharp hissing sound and an oxygen supply at the mouthpiece indicate the serviceability of the emergency valve.

To check the serviceability of the excess valve, inhale through the nose and, by exhaling, fill the breathing bag with air until the excess valve is triggered. A good overflow valve should open without causing significant breathing resistance.

To check the supply of oxygen with an open cylinder valve on the pressure gauge, check the pressure, which should be equal to the operating pressure - 200 kgf / cm² (20 MPa ± 1 MPa). To test the signal whistle, press sharply on its membrane.

Before entering a gas-polluted environment, put on a respirator. Switch on in the following sequence. Take off the helmet and clamp it between your knees, straighten the headband, put it on your head, taking a mouthpiece in your mouth. At the same time, open the cylinder valve with your right hand to the point of failure, turn the valve handwheel in the opposite direction by half a turn. Take several breaths from the respirator system until the lung demand valve operates. Put on the nose clip, attach the metal headband hooks to the rings of the junction box and put on the helmet. Wear smoke goggles in smoky environments.

Features of operation

Respirator "R-2", the price of which is only 115 rubles, must be used correctly. That is, during operation, the following rules must be observed:

1. Try not to allow mechanical damage to appear on the product. Otherwise, its protection will not be reliable.

2. Clean the inside with a soft, clean and dry cloth. Do not disinfect the product with solvents.

3. It is not allowed to store the respirator near open sources of flame, as well as in those places where direct sunlight can fall on it. At high temperatures, the product can melt.

4. After use, the respirator must be thoroughly shaken out. Naturally, all manipulations with it should be soft and smooth.

5. If the product shows tears or other damage, then it will have to be thrown away.

6. Try not to wet the respirator. From this, its technical characteristics deteriorate.

The presented product is made of environmentally friendly material, so it is safe for health. Subject to all operating conditions, such protection will serve you for a long time. Be healthy!

Product structure

It's pretty simple. Respirator "R-2" is made of three layers of different materials. The outer is made of polyurethane. As a rule, it has a protective color. The first layer is presented in the form of a polyethylene film, which does not allow air to pass through, and with it, accordingly, dust. It also has two valves built into it.

Between these two layers there is another one. Its task: to filter the air. It consists of polymer fibers. On the front part of the respirator "Р-2" has an outlet valve. For comfortable wearing, the product is equipped with a nose clip that prevents the mask from sliding over the eyes.

Thanks to elastic straps, the presented product is well fixed on the head. Moreover, they can be regulated.

Terms of use

Only a device that has not expired can be used for personal protection. The working respirator must be absolutely dry, as it loses its protective properties when wet.

After the selection of the device, it is carefully adjusted according to the degree of fit of the protective half mask.

To properly fit the protective device, you will need to follow a series of steps.

  1. Remove the protective respirator from the packaging, check its expiration date and the serviceability of each structural element.
  2. The U-2K device must be put on the face, and this must be done so that the nose and chin are inside the half mask. If this is difficult to accomplish, then you have taken the size of the protective device inappropriate for your height.
  3. A cotton sling is placed on the back of the head, the second sling is placed on the parietal part of the head.
  4. Using the available buckles, you need to adjust the size of the elastic straps so that the structure is firmly attached to the head and does not move even during intensive work.
  5. Design an aluminum nose clip to provide a good snug fit of the respirator in the bridge of the nose.
  6. If necessary, the contoured edges of the mask should be tightened to maximize its adherence to the face.

To check how tightly the respirator fits to your face, you need to do a little test: you need to hold the screen area with your hand so that air cannot flow through the valves. Next, try breathing in and out. If air cannot pass through the contours of the mask, but only inflates the structure, then you have put on the protective device correctly. In the event that air passes in the region of the bridge of the nose, you will need to press the nose clip structure more tightly against the nose. If all attempts to seal the half mask were in vain, this indicates that you have chosen the wrong size for the product.

Before starting to use, it is necessary to check the tightness of the protective respirator every time, and this should also be done after a long period of using the half mask during the day.

Since the U-2K device is airtight, condensation will accumulate in the space under the mask over time. To remove it, you will need to lower your head down several times and raise it again, while in parallel with the movements of the head, you need to perform several strong exhalations. If a large amount of moisture has accumulated inside the protective respirator, if possible, remove the device in a place safe for breathing, remove moisture, wipe the inside of the structure dry and put it back on its head.

After each use of the protective device, you must clean and decontaminate it. To do this, dust is removed from the outer part of the respirator by tapping the half mask on a hard surface. The surface inside the device must be treated with a gauze or cotton swab (sometimes they are moistened with an antibacterial agent, but more often with plain water). Carrying out internal processing, the structure of the half mask must not be turned outward. After processing, the U-2K respirator must be properly dried and put into a packaging bag, tightly sealed. Careful and proper care of the product allows it to be used many times - up to 12-15 times.

In order for the protective device to serve for a long time and properly, you will need to protect it from any mechanical damage. If through breaks are found in the structure of the device, any of the filter layers is damaged, the inhalation or exhalation valve is lost, the nose clip or attachment straps are damaged, then such a respirator cannot be used. The U-2K half mask should be protected from exposure to any solvents, since the foam rubber included in the protective layers of the half mask is destroyed under the influence of this chemical.

It should also be remembered that the polymer materials that make up the respirator can begin to melt if the ambient temperature reaches 75 ° C. For this reason, it is forbidden to store the product after sanitization on the panels of heating devices, dry it near an open flame, and use electric heaters.

How to use U-2K or R-2 respirators correctly, see below.

Requirements for the operation of respirator R-2

To ensure long-term service of the respirator, it is necessary to protect it from mechanical damage.

The respirator is not suitable for further operation in the event of the formation of through gusts of the half mask, gusts of plastic film, the absence of inhalation valves, nose clip, head straps. Wipe the inner surface of the half mask with a clean dry cloth or a cloth slightly moistened with water. It is forbidden to use organic solvents for impregnation of rags, since their contact with the half mask leads to a decrease in its strength or destruction.

The material of the half mask melts at a temperature of 80 ° C, therefore, the respirator must not be stored and dried near heating devices, fires, etc.

It is necessary to protect the respirator from the effects of atmospheric precipitation, as getting wet leads to an increase in inhalation resistance and loss of protective properties. After drying, the respirator can be used to protect the respiratory system from RP.

Technical characteristics of the respirator R-2:

  • Respirator weight: 60 gr.
  • Operating temperature range: minus 40 ... + 40 ° С
  • Shelf life: 7 years

Respirator
R-2 is a filtering
half mask equipped with two inhalation
valves, one exhalation valve
with protective screen, headband,
consisting of elastic and non-stretchable
ribbons and nose clip.

Outdoor
part of the half mask is made of polyurethane
(porous synthetic material),
and the inner one is made of thin airtight
films in which the inhalation
valves. Between polyurethane and film
there is a filter made of polymer fibers.

At
inhalation, air passes through the entire external
polyurethane surface and filter,
is cleaned of dust and through inhalation
valves enter the respiratory system.

At
As you exhale, the air comes out through
exhalation valve.

Manufactured
respirators R-2 in three sizes.

Selection
respirator is carried out in size,
which are determined by the results
measuring the height of the face (distance between
point of greatest deepening of the nose
and the lowest point of the chin).

table
17.1

Navigation¶

  • 2020/04/17 12:44 Obsidian has updated the AIHS GraFiS page.
    2020/01/19 16:59 Obsidian has updated the Air Compressibility Ratio page.
    2019/08/17 15:24 Obsidian has updated the Barrel A.
    2019/08/17 15:24 Obsidian has updated the Barrel B.
    2019/07/18 10:44 Aleksey has updated the page Linear Burn Rate.
    2019/04/10 14:10 Obsidian has updated the page Siberian Fire and Rescue Academy (Siberian Fire and Rescue Academy).
    2019/01/23 15:56 Obsidian has updated the Online GDZS Calculator page.
    2019/01/23 09:32 Obsidian has updated the AIHS GraFiS page.
    2018/12/04 11:01 Obsidian has updated the Fire extinguishing agent delivery devices page.
    2018/11/11 16:12 Obsidian has updated the Path Traveled by Fire page.
    2018/11/11 16:08 Obsidian has updated the Online GDZS Calculator page.
    2018/11/04 20:15 Obsidian has updated the Online GDZS Calculator page.
    2018/09/03 11:21 Obsidian has updated the Pumping and hose systems page.
    2018/08/27 09:34 Obsidian has updated the page Fighting fires in buildings with hinged ventilated facades.
    2018/07/31 16:54 Obsidian has updated the page Calculations of parameters of work in RPE.
    2018/07/31 15:00 Obsidian has updated the page Calculations of parameters of work in RPE.
    2018/07/24 09:26 Obsidian has updated the page Calculations of parameters of work in RPE.
    2018/07/17 14:46 Obsidian has updated the page Calculations of parameters of work in RPE.
    2018/06/19 20:56 Tor has updated the page Combined fire extinguishing schedule of changes in fire area, required and actual consumption of extinguishing agents over time.
    2018/05/18 16:40 Obsidian has updated the Firefighting Operations Headquarters page.
  • Random page
  • New page
  • All pages
  • Categories
  • Files
  • Pages that have links to this article

    • Gas and smoke protection service
    • Personal protective equipment for firefighters

    Pages referenced by this article

Site search

Description

Respirator R-2 is a means of individual protection of the human respiratory system. It is designed for use in dusty environments. Half masks of this brand are considered highly effective, have a wide purpose, as they protect not only the respiratory system, but also the body as a whole from various kinds of poisoning.

This respirator protects against the following types of dust:

  • mineral;
  • radioactive;
  • animal;
  • metal;
  • vegetable.

In addition, the P-2 respirator can also be purchased to protect against pigment dust, various pesticides and powdered fertilizers that do not emit toxic fumes. However, this type of protective device must not be used in humid environments or in places where there is a risk of contact with solvents. The manufacturer produces respirators P-2 in several sizes.

The main advantages of this product include:

  • high efficiency and dust resistance;
  • wide application and versatility;
  • possibility of application without the need for prior training;
  • ideal for children and the elderly with poor health;
  • long shelf life with the integrity of the package;
  • a warranty period of up to 7 years;
  • increased comfort during use: neither heat nor moisture is retained under the mask, and resistance is reduced on exhalation.

Technical task

The R-2U anti-aerosol respirator is designed to protect the respiratory system from all types of aerosols: - radioactive - dust - smoke - fog - with additional protection from radioactive iodine and its organic compounds.

Protection class FFP3 (high efficiency)

The respirator consists of a filtering half mask with an obturator.

The obturator, made of electrostatic contaminated material, provides reliable protection along the obturation strip. The respirator is equipped with an exhalation valve, which is located in the front of the half mask and is closed from the outside by a screen. The half mask is attached to the head with elastic straps and has a nose clip designed to press the half mask to the face in the area of ​​the bridge of the nose.

Respirator marking is applied with indelible paint and, in accordance with TR CU 019/2011 and GOST R 12.4.191-2011, contains: designation of the manufacturer's trademark, name of the respirator, number of the standard GOST R 12.4.191-2011, designation of TR CU 019/2011 , a single sign of product circulation on the market of the Member States of the Customs Union, type and class of protection, resistance to dust and indications of one-time use, date of production. Each respirator is individually wrapped in foil packaging. Requirements for technical characteristics: - Resistance to a constant air flow at a volumetric air flow rate of 30 dm3 / min, Pa (mm of water column), no more: while inhaling - 76; - Fastening strength of the exhalation valve body - withstands a tensile force of 10N for 10 s - corresponds; - The coefficient of permeability of the filtering material of the respirator for the test - substance oil mist (MT),% - 0.96; - The coefficient of aerosol penetration, according to the test - the substance oil mist (MT), through the respirator,% - 0.153; - Operating temperature range, С0: from -30 to +70; - Respirator weight - 25 g; - Guaranteed shelf life, years: 7.

- Anti-aerosol respirators have a universal size, including for children from 4 years old.

Completeness of delivery: - Respirator - 1 piece; - Blister - 1 piece; - Individual foil packaging for storing respirators, ensuring tightness throughout the entire storage period - 1 pc. - Memo on the use of a respirator, technical description and instructions for use - on each package;

- Passport of quality - 1 copy. for each corrugated box.

A batch of respirators is accompanied by a passport, which indicates the delivery set, the main characteristics of the product, and the manufacturer's warranty obligations.

Respirators must be supplied in the manufacturer's standard factory packaging with clearly visible markings applied in accordance with GOST 14192-96 “Interstate Standard. Cargo marking ", which makes it possible to unambiguously identify the type, quantity, batch number, year and quarter of manufacture of cartridges.

The packaging should not be damaged and should be sealed with the manufacturer's factory tape. The cost of packaging is included in the price of the goods, is not paid separately and cannot be returned. Packaging must ensure the safety of respirators during transportation by any type of transport, handling and storage during the warranty period.

Respirator R-2 is designed to protect the respiratory system from radioactive and ground dust.

The principle of operation of the filtering respirator P2 is based on the fact that the respiratory organs are isolated from the environment with a half mask, and the inhaled air is cleaned of aerosols in a package of filtering materials.